为什么排出口不能浸入水中?
<P><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-size: 12.0pt; mso-ascii-font-family: 'Times New Roman'; mso-hansi-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 1.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA">今天拿到一家泵厂的样本,在最后的安装图看到注意事项:排出口不能浸入水中,否则会引起虹吸现象。这里的虹吸现象是真空引起的水从入口到出口的自流动,对泵有什么负面的影响?</SPAN></P>4k3N:wY ~ s{<P><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-size: 12.0pt; mso-ascii-font-family: 'Times New Roman'; mso-hansi-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 1.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"></SPAN> </P>
<P><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-size: 12.0pt; mso-ascii-font-family: 'Times New Roman'; mso-hansi-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 1.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA">是不是会引起水锤损坏叶轮?还是别的?可以解释的详细点吗(问这样的问题请高手不要见笑)</SPAN></P> 停泵的时候把出口阀门关了不就行了吗?如果出口管安装有止逆阀也不会虹吸啊。 一方面还会引起出口的阻力,一般在停泵时都要先关掉出口阀门,所以不会出现虹吸 还应该看看这是什么形式的泵啊?
楼主能说的详细点吗?
液下泵/管道泵?或者其他? “排出口不能浸入水中,否则会引起虹吸现象”,这是个假命题,排出口不在水中也能虹吸。火电厂循环水系统就有虹吸现象,而且有的还有虹吸井。排出口浸入水中的虹吸有个好处,流态稳定,否则有喘振。 应该不是普通离心泵吧,最好问问厂家这样写是什么原因,也许是针对他们特殊产品,特殊结构而作的要求,否则的话正常操作使用,应该没有这样的要求. 排出口能侵入水中的 ;但在泵的出口短接上面必须接逆止门 在接出口门。要不在你的泵跳闸的时候就会出现虹吸现象造成泵的倒转(由于连通器的原理)损坏泵。如果你不装逆止门就会延长开泵的时间。单台泵就是必须安装逆止门(这样能满足连续生产的需要)。
回复 #4 lainj8283 的帖子
说得对。应该先弄清楚是什么形式的泵。 虹吸现象造成泵的倒转是不会对泵造成损坏的,问题是输送出去的液体到转会影响生产 第一次听说,一般泵出口管道中都装有缓冲逆止阀, 各厂家对水泵的注意事项是针对该泵的用户容易导致不应出现的现象及易忽视的情况而制定.就象你发现新大陆一样. 楼上说的应该是自吸泵,虹吸后泵内就没引水了。 很多用户对水泵的理解仅限于常规的现象,而供方着眼于易出现又不注意的事情.比如禁止倒转等规定. 应该是真空泵,液体倒流就会有液击的危险。页:
[1]